Alarm numberAlarm textCycleExplanation, Remedy
61101 "Reference plane
incorrectly defined"
Deep hole
drilling
Either different values must be entered
for the reference plane and return plane
for incremental definition of the depth or
an absolute value must be entered for
the depth.
61107"First drilling depth
incorrectly defined"
Deep hole
drilling
First drilling depth is not compatible with
total drilling depth.
61244"Thread pitch change
causes undefined thread"
Thread cuttingCheck thread geometry.
61602"Tool width incorrectly
defined"
Grooving in
STOCK
REMOVAL
Grooving tool is larger than programmed
groove width
61604"Active tool violates
programmed contour"
r"
Cutting in
STOCK
REMOVAL
Contour violation in relief cut elements
caused by the clearance angle of the
tool used, i.e. use a different tool or
check the programmed contour
61605"Contour incorrectly
programmed"
Cutting in
STOCK
REMOVAL
Illegal relief cut element detected
61606 "Error during contour
preparation"
Cutting in
STOCK
REMOVAL
During preparation of the contour an
error was detected, this alarm is always
output with NCK alarm 10930 ... 10934,
15800 or 15810 (see Diagnostics
Guide)
62200"Start spindle"Thread The spindle must be running before the
thread can be machined.
111 001Non-interpretable step in line %1
Explanation %1 = Line number
The step is not an element of ManualTurn.
ReactionAlarm display
EasyStep sequence is not loaded
Remedy Delete program step or edit program in operating area PROGRAMS of
SINUMERIK 840D or 810D (CNC mode).
111 002Not enough memory
Abort in line %1
Explanation%1 = Line number
EasyStep sequence contains too many steps
ReactionAlarm display
EasyStep sequence is not loaded
Remedy Edit the program in the PROGRAMS operating area of the
SINUMERIK 840D or 810D (CNC mode).
111 003ManualTurn: %1
Explanation %1 = Error number
Internal system message via the user interface of ManualTurn
ReactionAlarm display
RemedyAcknowledge error and inform Siemens.
111 004File does not exist or is incorrect: %1
Explanation%1 = Name of the file/contour
EasyStep sequence cannot interpret a step with contour programming.
Contour does not exist in directory.
ReactionAlarm display
NC start disable
RemedyLoad contour in directory.
111 005Error on interpreting the contour %1
Explanation%1 = Name of the contour
Contour is incorrect
Reaction Alarm display
NC start disable
Remedy Check machining sequence of contour
111 006Maximum number of contour elements exceeded %1
Explanation%1 = Name of the contour
Max. permissible number of 50 contour elements exceeded during
interpretation of machining sequence of a contour.
Reaction Alarm display
RemedyCheck machining sequence of a contour and correct, if necessary.
111 007Error in line %1 %2
Explanation%1 = Line number
%2 = Description of error
ReactionAlarm display
NC start disable
RemedyRemove the error.
111 008Spindle not synchronized
ExplanationSpindle not synchronized
Reaction Alarm display
RemedyAllow spindle to turn for at least one revolution (M3, M4)
111 009Insert new tool: T%1
Explanation T%1 = Tool number
Tool change program requests a new tool
ReactionAlarm display
NC Stop
Remedy Insert new tool
111 010Teach In Cancellation: Log overflow
Explanation Teach in procedure canceled.
ReactionAlarm display
Teach in file closed.
RemedyThe refresh rate must be increased by 100 to 200 ms in MD 9606:
$MM_CTM_SIMULATION_TIME_NEW_POS.

To order a Siemens Sinumerik Drive, please email sales@mrostock.com or call 1-800-691-8511.