The A06B-6096-H105 Alarm 8 can have several different meanings and variations.
Here at MRO Stock, we sell New and Remanufactured A06B-6096-H105‘s, and offer a competitive Repair and Exchange Program.
Please call 1-800-691-8511 or e-mail sales@mrostock.com for a quote or for more information on Fanuc products.
A06B-6096-H105 Alarm 8
(1)Meaning Inverter: DC link current alarm
(2)Cause and troubleshooting
(a)Disconnect the motor power leads from the SVM, and release the SVM from an emergency stop condition.
<1>If no abnormal DC link current alarm condition has occurred. Go to (b).
<2>If an abnormal DC link current alarm condition has occurred. Replace the SVM.
(b)Disconnect the motor power leads from the SVM, and check the insulation between PE and the motor power lead U, V, or W.
<1>If the insulation is deteriorated. Go to (c).
<2>If the insulation is normal. Replace the SVM.
(c)Disconnect the motor from its power leads, and check whether the insulation of the motor or power leads is deteriorated.
<1>If the insulation of the motor is deteriorated. Replace the motor.
<2>If the insulation of any power lead is deteriorated. Replace the power lead.
A06B-6096-H105 Alarm 8.9.A.
(1)Meaning Inverter: IPM alarm
(2)Cause and troubleshooting
(a)Disconnect the motor power leads from the SVM, and release the SVM from an emergency stop condition.
<1>If no IPM alarm condition has occurred. Go to (b).
<2>If an IPM alarm condition has occurred. Replace the SVM.
(b)Disconnect the motor power leads from the SVM, and check the insulation between PE and the motor power lead U, V, or W.
<1>If the insulation is deteriorated. Go to (c).
<2>If the insulation is normal. Replace the SVM.
(c)Disconnect the motor from its power leads, and check whether the insulation of the motor or power leads is deteriorated.
<1>If the insulation of the motor is deteriorated. Replace the motor.
<2>If the insulation of any power lead is deteriorated.
Replace the power lead.
A06B-6096-H105 Alarm 8.9.A
(1)Meaning Inverter: IPM alarm (OH)
(2)Cause and troubleshooting
(a)Check that the heat sink cooling fan is running.
(b)Check that the motor is being used at or below its continuous rating.
(c)Check that the cooling capacity of the cabinet is sufficient (inspect the fans and filters).
(d)Check that the ambient temperature is not too high.
(e)Replace the SVM.